Abstract: The hydraulic performance of a pilot filter in a water treatment plant is studied. This filter has been operatedwith negative pressures releasing air bubbles that clog the filter. Â In order to solve this problem, a modification in thefilter operation is proposed. Two hydraulic structures are evaluated, an orifice and a structure working as a dump.Several hydraulic parameters are evaluated: flow, pressure drop, effluent turbidity and filter run length. The dumpwith height of 10 cm work poorly under the design parameters due to high rates in small run length values. The 230mm orifice works adequately with the design parameters, with a run length of 54 hours, a mean flow of 160 l/s and agradient flow rate of 1,6 l/s. h. Â In addition, water quality is verified with NTE INEN 1108:2014.
Descargas
Descargas
Detalles del artículo
Citas
Acosta, R. (2008). Saneamiento ambiental e higiene de los alimentos,
Córdoba, Argentina: Brujas.
Aguinaga, A., & Crisanto T. (2014), Caracterización y cálculo de la cantidad de barros generados en el tratamiento de aguas arsenicales por el método Arcis-UNR. Revista politécnica. 34(1), 101-107 Obtenido de la base de datos Revista Politécnica.
American Public Health Association. (2010). Standard Methods for
Examination of Water and Wastewater, New York, Estados Unidos:
Publication Office.
Arboleda, J. (2000). Teoría y práctica de la purificación del agua, Bogotá, Colombia: Nomos.
García, F. (2010). Evaluación de baterías de filtros de tasa declinante y lavado mutuo de la planta de tratamiento de agua potable Mahuarcay. (Tesis de maestría). Universidad de Cuenca, Cuenca- Ecuador.
NTE INEN 110, (2014) Agua Potable. Requisitos, Ecuador: INEN.
Ojeda, J. (2013). Evaluación Del Sistema De Filtración De La Planta De Tratamiento Puengasí e Investigación en la Columna De Filtración
Piloto, (Tesis de maestría), Escuela Politécnica Nacional, Quito -
Ecuador.
Perea, L., Torres, P. & Cruz, C. (2014). Influence of the Flow Control
(Declining Rate - Constant Rate) on the Filtration Process in Drinking
Water Treatment. Ingeniería y Universidad, 18 (2), 217-234.
http://dx.doi.org/10.11144/Javeriana.IYU18-2.ifcd
Thompson, P., Brouckaert, B., Rajagopaul, R., Ngcekwa, M. and Mholongo, M. (Mayo, 2004). Design and operation of a constant level, constant rate pilot filtration plant. WRC Project 1395 Upgrading Of Existing South African Filtration. Conferencia llevado acabo en Water Institute of Southern Africa (WISA) Biennial, Cape Town, South Africa.
Villalba, L. (2004). Reingeniería de un sistema de filtración de tasa constante a un sistema de tasa declinante (Tesis de maestría) Escuela Politécnica Nacional, Quito -Ecuador.